•   Internal and external sand flushing technology

    Adopting advanced internal and external sand flushing technology, the surface roughness reaches Sa2.5-3.0 level, and the paint adhesion is stronger. The cabin adopts The American imported anti-corrosion coating brand "TNEMEC" has no odor and is non-toxic.
  •  Lightweight thin shell door

    Lightweight, easy to open and close the door, with a lightweight eccentric mechanism for closing the door. The eccentric mechanism is equipped with a cabin pressure automatic locking device and a machine Double protection of mechanical locking ensures absolute safety for cabin operators when opening doors.
  •  Ultra long and high-quality stretcher bed (the first of its kind in China)

    For the convenience of patients entering and exiting the cabin, our company has designed an extra long stretcher bed (with a high-quality stainless steel bed surface) and installed a fixed locking device, The longest stretcher bed can be pulled out by 1.6 meters, which has extremely high clinical practical value.
  •  Micro pressure automatic sealing door seal

    After the cabin door is closed, as long as pressure is applied to the cabin, before the cabin pressure gauge is pressurized, the double-sided lip of the door seal can connect with the The inner wall of the dovetail groove automatically conforms to the plane of the door, and as the cabin pressure increases, its adhesion force increases, and the cabin pressure itself is established Good sealing effect.
  •  Cold and warm type external circulation air conditioner (the first of its kind in China)

    Based on the development characteristics of oxygen chambers abroad, our company has successfully developed a design that places the evaporator of the air conditioning system outside the chamber. Firstly, it avoids The evaporator has been leaking copper pipes for a long time. Secondly, it solves the problem of long-term corrosion of the cabin, which directly affects the service life of the oxygen chamber. Circulating fan inlet The exit is equipped with fire barriers, which increases the safety of the pure oxygen chamber. This air conditioner is developed by our company. Currently exclusively owned.
  •  Oxygen humidification system

    The oxygen pressurized into our company's pure oxygen cabin is first passed through a humidifier before entering the cabin, and the relative humidity has reached About 70% (based on temperature), there is a humidity indicator on the control panel that displays real-time humidity inside the cabin and tracks it in real time. spray The humidity device can easily humidify to the desired level according to the instructions of the hygrometer.
  •  Safety monitoring system

    All power sources are not allowed to enter the cabin, and there is no electrical spark hazard inside the cabin.
  •  Conductive clamp

    When the patient is moving inside the cabin, static electricity is generated in the body, and the static electricity is clamped on the patient's wrist and connected to the cabin through braided wire Connect, so that the induced static electricity generated by the human body can be introduced into the grounding device of the cabin at any time and enter the ground.
  •  Computer automation operation control system

    The computer automation operation control system has been widely used in medical air pressurized oxygen chambers, and the application of this system has improved The safety and reliability of equipment operation, as well as the level of automation control, have been improved, reducing the labor intensity of cabin operators and ensuring safety and reliability Advantages such as easy operation and good stability.
Copyright © Shanghai 701 Yangyuan Hyperbaric Oxygen Chamber Co., Ltd CO.,LTD.